Elapsed Time

Calculate the elapsed time in milliseconds after the measurement starts.
You can add this processing item to a scene and setup is not required.
Used in the Following Case
• When combining with the conditional branch for stopping measurement after the specified
processing time has elapsed.
1.
2.

Elapsed time

3.
Conditional Branch
4.
Search
5.
Parallel Judge
6.
End
• When calculating the processing execution time of a unit
Set up the elapsed time before and after the unit respectively and specify
the arithmetic expression required for calculating their
1.
Elapsed time
2.
Search
3.
Elapsed time
4.
Calculation
FH/FZ5 Processing Item Function Reference Manual
Scroll
Branch condition
Elapsed time ≤ 100 → Unit 4
Elapsed time > 100 → Unit 7
7.
End
By setting up the arithmetic expression for
"3. Elapsed time"-"1. Elapsed time",
the measuring time of Unit 2 to 3 can then
be calculated.