Judgement Condition (Color Data) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Judgement Condition (Color Data)

This item specifies the judgement condition for measurement results.
1
When the setting has been changed,
click [Measurement] to verify whether
measurements can be made correctly.
2
In the RGB Judgement condition area, set the judgement condition.
Setting item
Color difference
Color deviation
HSV parameters can also be used to set the judgement condition.
1
Place a check at [Automatic].
2
In the Image Display area, specify the
color range you want to detect by
dragging the cursor from the upper left
corner to the lower right corner of that
area.
The color of the specified area is automatically
set.
Setting item
Automatic
H
S
V
312
Color Data
Setting value
Specify the upper and lower limit values for the difference between the
0 to 442
average color of the measurement region and the reference color.
Specify the upper and lower limit values for the deviation of the average
0 to 221
color in the measurement region.
Setting value
[Factory default]
• Checked
Specifying the color to be measured on the image automatically sets the
• [Unchecked]
hue, saturation, and brightness.
0 to 359
Set the color phase (difference of color hues).
0 to 255
Set color saturation (difference of color saturation).
0 to 255
Set the brightness (difference of brightness).
Description
Description
FH/FZ5 Processing Item Function Reference Manual

Hide quick links: