2
To register or correct a model, click [Model setting].
The Model setting window is displayed.
Note
When displaying the Model setting window, for the image files in the folder specified in [Folder name] is checked.
[Image format mismatch] is displayed if the size or color of the image file and the input image is different.
3
Specify the destination to save the model image and set whether or not to use a measured
image as the model image.
Setting item
Folder name
[Filtered image
logging]
Save this filtered
image
Important
When saving image is selected in [Filtered image logging], images that can be used as a model are saved in the
folder specified in [Folder name] during measurement. Register the model from among the images included in the
model image list again in this setting after measurement.
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
Specify the folder to store the generated model image or the folder where
---
the model image is stored.
Set whether or not to save measured images as subjects of model
registration.
• None
• [None]
Select this to use the current image as the model image without saving
• All
the image to be filtered. Then click [Save] to add the current image to
the model image list.
• All
Select this to save the image to be filtered as a model image.
---
Press the [Save] button to save the current image as the Model image.
Description