Timing Chart (Control Flow Plc Link) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

No.
123
Unit judgement in timeout
5000
Wait state clear command

Timing Chart (Control Flow PLC Link)

To execute a command using a Control Flow PLC Link processing item during a measurement flow, control the
sensor controller paying attention to the timing of the signals from the external device. Refer to the timing chart
below.
Example: The measurement command is executed by PLC Link, and the processing unit data setting command
is executed by Control Flow PLC Link processing during measurement.
CMD-CODE
Command code
CMD-PARAM
Command parameter
CMD-EXE
Control command execution signal
CMD-FLG
Command execution completion signal
BUSY
Busy signal
CMD-CODE
Command code
RES-CODE
Response code
RES-DATA
Response data
CMD-XWAIT
Flow command wait signal
CMD-XEXE
Flow command execution signal
CMD-XBUSY
Flow command busy signal
CMD-XFLG
Flow command completion signal
1. Set the command code and command parameters to be executed by the user (PLC). (In the above
example, this is the measurement command.)
2. The user (PLC) turns ON the control command execution signal (EXE signal).
3. The sensor controller turns ON the processing busy signal (BUSY signal).
4. When the processing unit is executed inside the measurement flow, the sensor controller turns ON the
measuring command standby signal (XWAIT signal).
5. The user (PLC) sets the command code to be executed during measurement and the command
parameters, during measurement, and turns ON the measuring command execution signal (XEXE signal).
(In the above example, this is the Set Unit Data command.)
6. The sensor controller turns ON the measuring command executing signal (XBUSY signal).
7. After setting the command code executed during measurement, the response code, and response data,
the sensor controller turns ON the flow command completion signal (XFLG signal), and turns OFF the
measuring command executing signal (XBUSY signal).
8. The user (PLC) turns OFF the flow command execution signal (XEXE signal). If the signal does not turn
OFF within the set timeout time, the control flow advances directly to step 14.
9. The sensor controller turns OFF the measuring command completion signal (XFLG signal).
850
Control Flow PLC Link
Data name
Set/Get
Set only
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1
2
3
4
5
6
Set/Get
0: NG
1: OK
1: Clear the wait state
7
8
9
10
FH/FZ5 Processing Item Function Reference Manual