List of Sensitive Search Items
Item name
This item registers the pattern characteristic of the measurement image as a model.
Model parameter values can be changed as needed to address unstable measurement results or to
Model
increase the processing speed. Normally, the factory default value will be used.
Reference: Model Registration (Sensitive Search) (p.120)
This item is used to set up the measurement area.
Region setting
Instead of measuring the entire input image, narrowing the measurement area shortens the processing time.
Reference: Region Setting (Sensitive Search) (p.123)
This item can be changed if necessary. Specify a position in the model that should be used as the detection
Detection
coordinates during measurement. Usually, the central position of the set model is registered as the detection
point
coordinates.
Reference: Detection Point (Sensitive Search) (p.123)
This item can be changed if necessary. Specify the reference position within the camera's field of view.
Ref. setting
Reference: Reference Setting (Sensitive Search) (p.124)
This item specifies the judgement condition for measurement results. Specify the criteria to judge the
Measurement
measurement result if the X and Y coordinates and the correlation values with the model are OK.
Reference: Measurement Parameters (Sensitive Search) (p.126)
This item can be changed if necessary. Normally, the factory default value will be used.
Output
Use the output parameter to specify how to handle the coordinates.
parameter
Reference: Output Parameters (Sensitive Search) (p.127)

Model Registration (Sensitive Search)

Register the parts to measure as the model.
The position at the time of registration is also registered in the model information. Place the measurement object
in the correct position when registering a model.
1
In the Item Tab area, click [Model].
When setting a new model, you do not have to click [Model].
2
Use the drawing tools to specify the model registration range.
3
To save the entire image used for model
registration, place a check at the "Save
reg. model" option. Also, when
registering a model but not holding the
disable setting for the sub-region set
during the last time the model was
registered, uncheck the "Keep disabled
state" option.
Setting item
Keep disabled state
Save reg. model
4
Click [OK] / [Apply] in the Figure setting area.
• [OK]: Changes the settings and returns to the previous menu.
• [Cancel]: Changes are discarded. Returns to the previous menu.
• [Apply]: Updates the settings without leaving edit window.1
120
Sensitive Search
Set value
[Factory default]
• [Checked]
When the model is registered, this holds the disable setting for the
• Unchecked
sub-region set during the last time the model was registered.
• Checked
To save the entire image used for model registration, place a check at
• [Unchecked]
this option.