Calibration Result (Plc Master Calibration) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Calibration Result (PLC Master Calibration)

The created calibration data is displayed in this item. The calibration data can be adjusted directly using the Edit
function.
It is also possible to confirm the sampling data used for the calculation.
1
In the Item Tab area, click [Calibration result].
2
This item confirms the calibration data you created.
Setting item
Display
setting
Calibaraiton data
Sampling data list
772
PLC Master Calibration
Setting value
[Factory default]
Display
0 to 7
setting
[0]
Data No.
Item
Sets the calibration data number that displayed the
calculation results.
Displays details about the calibration parameters.
Clicking [Enable direct edit] will let you change the numbers for A to F.
If any number has been changed, the message "This data has been
directly edited" appears at the left of [Enable direct edit].
Displays sampling data used for creating the calibration parameters.
Normally, non-existing axis value will be 0 when Xθ, Yθ, θX, θY. X or Y
stage is selected.