Output Parameters (Trend Monitor); Key Points For Test Measurement And Adjustment (Trend Monitor) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Extended format
Line
1
2
3
4
5
:
100002
Note
• The default for the file name is the data save date (example: 0410.csv). If it is half-width alphanumeric characters,
it can be changed arbitrarily.
3
In the "Save setting" area, click [Save].
Data is saved to a USB memory stick or SD Memory Card.

Output Parameters (Trend Monitor)

Specifies whether or not the judgement results of this processing unit is reflected in the scene overall judgement.
1
Click [Output parameter] in the Item Tab area.
2
Choose whether or not to reflect this in the scene overall judgement in "Reflect to overall
judgement" area.
Setting item
Reflect to overall
judgement

Key Points for Test Measurement and Adjustment (Trend Monitor)

The following content can be confirmed in the "Detail result" area using text.
Displayed items
Judge
Measurement
Max
Mini
Standard deviation
Plus 3σ
Plus σ
Average
670
Trend Monitor
Text
<Maximum>, <Minimum>, <Deviation>, <Plus 3σ>,
<Plus σ>, <Average>, <Minus σ>, <Minus 3σ>, <Count>,
<OK count>, <NG count>, <Warning count>, <Yield>
0, <judgement result, latest>, <measured value, latest>,
<Time>
1, <Last 1 judgement result>, <Last 1 Measurement>,
<Time>
2, <Last 2 judgement result>, <Last 2 Measurement>,
<Time>
:
99999, <Last 99999 judgement result>,
<Last 99999 Measurement>, <Time>
Set value
[Factory default]
• [ON]
• OFF
Judgement result
Latest measured value
Max. measurement value during recording period
Min. measurement value during recording period
Standard deviation for measurement values during recording period
Average of measurement values during period recorded + standard deviation of the
measurement values × 3
Average of measurement values during period recorded + standard deviation of the
measurement values
Average value for measurement values during recording period
Statistical data
Last
Last 1
Last 2
:
Last 99999
Description
Enables choosing whether or not the judgment results of this
processing unit is reflected in the scene overall judgement.
Description
FH/FZ5 Processing Item Function Reference Manual
Description
Measurement result
(Max: 100000
items)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents