Omron FH-3 Series Reference Manual page 44

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Inputting and Setting Values (Value Setting)
Enter calibration data directly with numerical values.
1
In the Item Tab area, click [Calibration].
2
In the "Calibration setting" area, select
"Parameter".
3
In the "Parameter" area, specify values
for the "Coordinate", "Origin" and
"Magnification".
Item
Coordinate
Origin
Magnification
4
Click [Generate calibration parameters].
The calibration parameters will be generated.
42
Camera Image Input
Set value
[Factory default]
• [Lefthand]
• Righthand
• [Upperleft]
• Lowerleft
• Center
0.00001 to 9.99999
Left-hand type: Clockwise is forward
when specifying the coordinates.
Right-hand type: Counter-clockwise is
forward when specifying the coordinates.
Select where the origin of the
actual coordinates will be.
Specify the ratio of 1 pixel to the actual dimensions.
FH/FZ5 Processing Item Function Reference Manual
Description
Lefthanded
0
Righthanded
Upper left of screen
Center of screen
Lower left of screen
X
Positive
Y
Y
Positive
0
X

Hide quick links: