Specify point (Camera Calibration)

Specify a given pixel to make the calibration setting. Calibration parameters can be calculated by setting the
actual coordinates of specified locations. Up to 100 points can be set.
1
In the Item Tab area, click [Specify point].
2
In the [Display] area, click [Change display] to select the camera image type.
Setting item
Display
3
Click the first point on the screen.
4
Set the actual coordinates for the
specified point.
The actual coordinate input window is
displayed.
Actual coordinate
Point coordinate X, Y
Actual coordinate X, Y
5
Set the 2nd, 3rd and subsequent points in the same way.
6
Edit or delete the coordinates as
required.
Select the points to be edited or deleted from
the list.
Click [Edit] or [Delete].
To delete all points, click [Clear All].
7
Click [Generate calibration parameters].
The calibration parameters will be generated.
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
Through image
The latest image is always input from the camera and displayed.
display
[Freeze image
The image that was scanned in the immediately preceding measurement
display]
is displayed.
0 to 9999.9999 [Point you clicked in the window]
-99999.9999 to 99999.9999 [0]
Description
Setting value [Factory default]
4
815