Key Points for Test Measurement and Adjustment (Glue Bead Inspection)

The following content is displayed in the "Detail result" area as text.
Displayed items
Judge
State
Min. width
Max. width
Gap width
Key Points for Adjustment
Select the adjustment method referring to the following points.
When a path creation error occurs
State
Either the start position or end position
is set outside the measurement region.
Either the start position or end position
is yet to be registered.
Either the start position or end position
is inappropriate to fully enclose coating.
Coating is gapped between the start
position and end position.
Width between paths of a spiral path
is sometimes measured.
When judgement is NG
State
The judgement is NG (insufficient
memory)
502
Glue Bead Inspection
Judgement result
Coated condition of measured coating
Maximum width of measured coating
Minimum width of measured coating
Gap width of measured coating
Parameter to be adjusted
Region setting
Region setting
Region setting
Region setting
Region setting
Parameter to be adjusted
Region setting
Description
Troubleshooting
Set the start position or end position, whichever is
applicable, inside the measurement region.
Set the start position or end position, whichever is
applicable.
Register the start position or end position,
whichever is applicable, so that the two positions
are set vertically across coating.
If coating is gapped in the middle, register multiple
coating gap inspections and set separate inspection
parts.
Divide the spiral into regions corresponding to
individual turns and set a unit for each region.
Troubleshooting
Adjust the region so that the reference path
becomes shorter.
FH/FZ5 Processing Item Function Reference Manual