3
In the "Display setting" area, set the
image display settings.
Setting item
Binary image
4
When the setting has been changed,
click [Measure] in the "Detail" area to
verify whether measurements can be
made correctly.
5
Set up the judgement condition.
Note
• The values beside each item are measurement results of the displayed image. Take these values into
consideration to determine the upper and lower limit values.
Setting item
Route len. (Long)
Route len. (Short)
Min. width
Max. width
Avg. width
Gap width

Output Parameters (Glue Bead Inspection)

Set how measurement results are output to an external device. This item can be changed if necessary. Normally,
the factory default value will be used.
1
Click [Output parameter] in the Item Tab area.
2
Specify each of the following items.
Setting item
Output coordinates
Calibration
Reflect to overall
judgement
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
• [Checked]
• Unchecked
Setting value
[Factory default]
0.0000 to 99999.9999
[0.0000] to [99999.9999]
0.0000 to 99999.9999
[0.0000] to [99999.9999]
0.0000 to 99999.9999
[0.0000] to [99999.9999]
0.0000 to 99999.9999
[0.0000] to [99999.9999]
0.0000 to 99999.9999
[0.0000] to [99999.9999]
0.0000 to 99999.9999
[0.0000]
Setting value
[Factory default]
• [After scroll]
As measurement results, select whether to output coordinate values to
• Before scroll
external devices before or after the position compensation is applied.
Select whether to reflect the calibration in the values output to the
• [OFF]
external device as measurement results.
• ON
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
• [ON]
Specify whether or not the judgement results of this processing unit is
• OFF
reflected in the scene overall judgement.
Description
Use this option when binary images are displayed.
Description
Set the range of path lengths (long) that is judged to
be OK.
Set the range of path lengths (short) that is judged
to be OK.
Set the minimum width that is judged to be OK.
Set the maximum width that is judged to be OK.
Set the average width that is judged to be OK.
Set the gap width along a path that are judged to be
OK.
Description
501
Glue Bead Inspection
2