Item name
This item can be changed if necessary. Normally, the factory default value will be used.
Output
Specify whether to reflect the judgement result to the overall judgement of the scene.
parameter
Reference: Output Parameters (Trend Monitor) (p.670)

Measurement Value (Trend Monitor)

Select the measurement value to be viewed on the trend monitor.
One item can be displayed for each trend monitor unit.
1
Click [Measurement] in the Item Tab area.
2
In the "Expression" area, click [...] in
"Measurement data", and measurement
values to be monitored are set up using
an expression.
The Setting Expression window is displayed.
Select a unit number processed before [Trend
Monitor]. Even if the unit number after [Trend
Monitor] is selected, the graph will not display.
3
Set up number of items to save as
necessary.
Setting item
Number of saving
Important
• Trade offs between number of items saved and the sensor controller performance include the following.
• There is a difference in amount of memory used of approximately 2 MB between 1000 items and 100000 items.
Please confirm the amount of memory remaining prior to performing set up.
FH/FZ5 Processing Item Function Reference Manual
Set value
• [1000]
Set the number of measurement values to save.
• 5000
A maximum of 5000 items can be displayed on the main screen.
• 10000
Measurements that exceed 5000 items are displayed using
• 50000
toggling of pages.
• 100000
Description
Description
4
663
Trend Monitor