Omron FH-3 Series Reference Manual page 110

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

No.
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
1000 + NN × 4
(NN = 0 to 31)
1001 + NN × 4
(NN = 0 to 31)
1002 + NN × 4
(NN = 0 to 31)
108
Search
Data name
Upper limit of measure X
Lower limit of measure X
Upper limit of measure Y
Lower limit of measure Y
Upper limit of the angle
Lower limit of the angle
Upper limit of the corr.
Lower limit of the corr.
Save registered model
Candidate Point Level
Sort order
Search No.
Upper limit of count
judgement
Lower limit of count
judgement
Multiple output
Setting unit of reference
coordinate
Setting type of reference
coordinate
Update the reference angle Set/Get
Reference angle
Setting unit of detection
coordinate
Setting type of detection
coordinate
Use point coordinate
before scroll
Position X before scroll
Position Y before scroll
Angle before scroll
Count
Correlation value
Measure X
Measure Y
Set/Get
Set/Get
-99999.9999 to 99999.9999
Set/Get
-99999.9999 to 99999.9999
Set/Get
-99999.9999 to 99999.9999
Set/Get
-99999.9999 to 99999.9999
Set/Get
-180 to 180
Set/Get
-180 to 180
Set/Get
0 to 100
Set/Get
0 to 100
0: OFF
Set/Get
1: ON
Set/Get
0 to 100
0: Correlation value ascending
1: Correlation value descending
2: X ascending
Set/Get
3: X descending
4: Y ascending
5: Y descending
Set/Get
0 to 127
Set/Get
0 to 128
Set/Get
0 to 128
0: OFF
Set/Get
1: ON
Set/Get
-1 to 9,999
0: Numberical 1: Unit
Set/Get
0: Not update 1: Update
Set/Get
-180 to 180
Set/Get
-1 to 9,999
0: Numberical 1: Unit
Set/Get
0: Not use 1: Use
Set/Get
Set/Get
-99999.9999 to 99999.9999
Set/Get
-99999.9999 to 99999.9999
Set/Get
-180 to 180
Set/Get
1 to 128
Get only
0 to 100
Get only
-99999.9999 to 99999.9999
Get only
-99999.9999 to 99999.9999
FH/FZ5 Processing Item Function Reference Manual
Data range

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents