Output Parameters (Ec Corner); Key Points For Test Measurement And Adjustment (Ec Corner) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Output Parameters (Ec Corner)

Set how to treat the coordinates to be output to the external device as measurement results. This item can be
changed if necessary.
1
Click [Output parameter] in the Item Tab area.
2
Specify each of the following items.
Setting item
Output coordinates
Calibration
Reflect to overall
judgement

Key Points for Test Measurement and Adjustment (Ec Corner)

The following content is displayed in the "Detail result" area as text.
Displayed items
Judge
Corner X
Corner Y
Angle
Number of detections
The image specified in the Sub-image number in image display setting is displayed in the image display area.
Sub image.
0
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are unstable
Parameter to be adjusted
Measurement
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
• [After scroll]
As measurement results, select whether to output coordinate values to
• Before scroll
external devices before or after the position compensation is applied.
Select whether to reflect the calibration in the values output to the
• [OFF]
external device as measurement results.
• ON
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
• [ON]
Specify whether or not the judgement results of this processing unit is
• OFF
reflected in the scene overall judgement.
Judgement result
X Coordinate of measured corner
Y coordinate of measured corner
Formed angle of measured corner
Number of detections of corner
Explanation of image to be displayed
Measurement image
Reduce the distance between the upper and lower limits of line length range for extracting
lines, to reduce false detections.
Raise the line connection level to prevent the lines constituting the corners to be detected from
being interrupted.
Set the narrowest possible conditions for extracting corners, to reduce false detections.
Description
Description
Troubleshooting
2
197
Ec Corner

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents