Measurement Results For Which Output Is Possible (Label Data); External Reference Tables (Label Data) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Measurement Results for Which Output Is Possible (Label Data)

The following values can be output using processing items related to results output. It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judge
Label No.
Area
Gravity X-coordinate
Gravity Y-coordinate

External Reference Tables (Label data)

No.
0
Judge
5
Label No.
6
Area
7
Gravity X
8
Gravity Y
101
Output Coordinates
102
Calibration
Reflect to overall
103
judgement
120
Label unit
121
Label No.
122
Upper limit of the area
123
Lower limit of the area
124
Upper limit of gravity X
125
Lower limit of gravity X
126
Upper limit of gravity Y
127
Lower limit of gravity Y
354
Label Data
Character string
JG
Judgement result
LN
Label No.
AR
Area
X
Center of gravity X position
Y
Center of gravity Y position
Data name
Set/Get
Get
Get
Get
Get
Get
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Set/Get
Description
Data range
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
0 to 2499 (For FZ5-3xx, FZ5-6xx)
0 to 9998 (For FH-1xxx, FH-3xxx, FZ5-8xx, FZ5-11xx, FZ5-
12xx)
0 to 999999999.9999
-99999.9999 to 99999.9999
-99999.9999 to 99999.9999
0: After scroll
1: Before scroll
0: OFF
1: ON
0: ON
1: OFF
-1: None
0 to 9999
0 to 2499 (For FZ5-3xx, FZ5-6xx)
0 to 9998 (For FH-1xxx, FH-3xxx, FZ5-8xx, FZ5-11xx, FZ5-
12xx)
0 to 999999999.9999
0 to 999999999.9999
-99999.9999 to 99999.9999
-99999.9999 to 99999.9999
-99999.9999 to 99999.9999
-99999.9999 to 99999.9999
FH/FZ5 Processing Item Function Reference Manual