Omron FH-3 Series Reference Manual page 264

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

2
You can specify enable/disable for each
edge measurement number.
Setting item
Sub-region No.
3
Set the value of each item in the "Measurement" area.
For color cameras:
Edge color specification is OFF.
Setting item
Edge Upper
Edge Lower
Edge color level
262
Scan Edge Width
Set value
[Factory default]
[0] to 99
• [Checked]
Enabled
• Unchecked
• [Forward area]
• Reverse area
Set value
[Factory default]
• Position (%) for
width of a color
0 to 100
[50] to [100]
• Value of color
0 to 442
[20] to [442]
0 to 442
[100]
Description
Set the edge measurement number for which the edge profile is
displayed.
Specify enable/disable for the displayed edge measurement
number. When disabled (unchecked) is specified, measurement is
not performed.
Forward area: The edge is searched for from the start point of the
area toward the end point.
Reverse area: The edge is searched for from the end point of the
area toward the start point.
Edge color specification is ON.
Description
Set a range of a color difference level with which the edge is
detected.
Reference: "Appendixes Measurement Mechanism Edge
Detection Measurement" in the "Vision System FH/FZ5 Series
User's Manual (Z365)"
This emphasis level can be specified only if the edge color to
detect is specified.
FH/FZ5 Processing Item Function Reference Manual