Important
• In the following cases, the system operates in Multi-input mode, regardless of the settings for Mode.
: Camera Image Input HDR or Camera Image Input HDR Lite is used.
: Multiple Input image processing items are used in one Multi-trigger Imaging Task block.
: FZ-SQ□□□□ camera is used with its light ON.
: Input image processing item is inserted outside of the range between Multi-trigger Imaging and Multi-trigger Imaging
End processing items.
• There are restrictions below when FZ-FQ□□□□ camera is used with its light ON.
: All Camera Image Input processing items operate with the settings for the Camera Image Input of the first Multi-trigger
Imaging Task in the flow.
: The system operates in Multi-input mode disabled. (It takes longer time to turn ON the READY signal).
: When the light of FZ-FQ□□□□ camera is OFF, the camera operates in the same way as other camera does.
Key Points for Adjustment
Select the adjustment method referring to the following points.
When there is poor image capture results
Parameter to adjust
Verify that there are no additional Camera Image Input units between a Multi-Trigger
Imaging block and the first Multi-Trigger Imaging task.
If there is a Camera Image Input related unit in this position, image capture results will
not be correct.
When using Multi-Trigger Imaging, ensure that Camera Image Input related units are
Edit flow
contained inside a Multi-Trigger Imaging task.
The number of Multi-Trigger Imaging tasks does not match the number of STEP
signal inputs.
Verify that the number of Multi-Trigger Imaging tasks and the number of STEP signal
inputs match and try image capture again.