Adjusting of the measurement processing speed
You can use the following methods to improve measurement processing speed.
When the processing speed is late
Parameter to be adjusted
Region setting
Reference: Region
Setting (Shape Search III)
(p.176)
Model
Reference: Model
(Shape Search III) (p.170)
Measurement
Reference: Measurement
parameter (Shape Search
III) (p.179)
Adjustments for other than measurement processing speed
There are the following methods to adjust for other than measurement processing speed.
When Judement result is NG (insufficient memory)
Parameter to be adjusted
Region setting
Reference: Region
Setting (Shape Search III)
(p.176)
Model
Reference: Model
(Shape Search III) (p.170)
Measurement
Reference: Measurement
parameter (Shape Search
III) (p.179)
FH/FZ5 Processing Item Function Reference Manual
• Measurement processing time takes long time becasue the measurement region is broad.
Set the measurement region as nallow as possible.
• Measurement processing time takes long time becasue the measurement region is broad.
Set the Model region as nallow as possible.
• A complicated shape is registed as a Model.
Check [High speed aligment mode] in Model parameter if target pattern is not a complex one.
• If there are too many false detections in a rough search.
Raise [Acceptable distortion level] If workpieces that should be judged OK vary little.
• The measurement process is longer for for high precision measurement than it is for sub-
pixel measurement. Uncheck [High-Prec.] when the position accuracy is enough high.
• There is a possible that needless rotational work piece is measured its angle.
Uncheck [Rotation] in this case.
• A work piece that its angle range is nallow is measured with huge angle range.
Set upper and lower level of [Angle range] to small when point-symmetry work pieces are
measured.
• Memory use is too high due to the measurement region being too large.
Set the measurement region as nallow as possible.
• Memory use is too high due to the size of the model being large.
Set the Model region or [Size change] of [Size change] as nallow as possible.
• Memory use is too high when [Back clutter] is checked.
Uncheck [Back clutter] and process the edge using processing units for compensate image
(refer to Chapter 3).