Measurement Results for Which Output is Possible (Shape Search III)

The measurement result of Shape Search III is the following. This result is displayed on the measurement result
area, and output to extra device is possible by using processing units related on output result.
Measurement items
Judge
Number of detections
Correlation value
*1
Position X
*1
Position Y
Angle θ
Reference X
Reference Y
Reference angle
Detection point RX
Detection point RY
Correlation value N (N = 00 to
127)
Position N (N = 00 to 127)
Position N (N = 00 to 127)
Angle N (N = 00 to 127)
186
Shape Search III
Character
string
JG
Judgement result
Number of search items detected
C
If none detected, 0
CR
Correlation value with the model
X
X coordinate of the position where the model is detected
Y
Y coordinate of the position where the model is detected
TH
Angle of the position where the model is detected
SX
X coordinate of the reference position of the registered model
SY
Y coordinate of the reference position of the registered model
ST
Angle of the registered model
RX
X coordinate of the registered model
RY
Y coordinate of the registered model
CRN
Detected search N correlation value (N = 00 to 127)
XN
Detected search N position X (N = 00 to 127)
YN
Detected search N position Y (N = 00 to 127)
THN
Detected search N angle TH (N = 00 to 127)
Description