Setting display
Perform the display setting if required.
Setting item
Image type
Mask region color

Reference Setting (Labeling)

This item can be changed if necessary. When the region is set, the reference position is automatically set at the
center of gravity of the measurement region. In the same way for the reference area, when the region settings
are made, they are set automatically based on the measurement region.
This item can be used to change the reference position to any desired position.
A reference position can be set either directly or by referencing a unit.
Specifying directly
Click a position on the image you want to use as a reference position, or set coordinate data for that point.
1
In the Item Tab area, click [Ref. setting].
In the display area, the current reference
position will be displayed as the crosshair
cursor.
2
In the "Method" area, select "Numerical".
3
Click the position to be set as the
reference.
4
Make fine adjustments using numeric
value inputs or the arrow buttons as
required.
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
Select the type of an image to be displayed.
• Measure image
Measure image: Measured image
• Mask binary image
Mask binary image: Binarized image for masking
• [Mask and image]
Mask and image: Post-masking image
• [Black]
• White
Select the display color of the mask region.
• Red
A part of color which is specified in [Mask region color] is not
• Green
measured.
• Blue
Description
2
339
Labeling