Key Settings; Setting The Measurement Width (Scale) - Omron Z4LB V2 Instruction Manual

Parallel beam linear sensor
Table of Contents

Advertisement

Key Settings

4-2
Key Settings
4-2-1

Setting the Measurement Width (scale)

The following settings are required only if the Z4LB-S30V2 Sen-
sor is to be used with the measurement unit set to mm.
The following steps make it possible to change the measure-
ment width. For details, refer to 3-1 Selecting the Measurement
Unit.
Refer to Z4LB-S30V2 Sensor under 3-1 Selecting the Mea-
surement Unit (p. 24).
Procedure
There are two procedures that can be used to set thresholds. Se-
lect the easier method according to the application. The following
example shows how to set the measurement width in function
selection mode.
The figure 1 flashes.
38
1 Set the operating mode selector to RUN.
2 Press the TEACH Key for 3 s.
The Sensor will enter function selection mode.
3 Press the Up Key to go to measurement width setting.
scale
Measurement width
4 Press the SET Key.
5 Press the UP Key twice to change 1 to 3.
10
6 Press the SET Key.
The set value will be entered and the display will flash twice.
7 Press the TEACH Key to return to RUN mode.
Section
20
4-2
30

Advertisement

Table of Contents
loading

Table of Contents