Measurement Results For Which Output Is Possible (Di Branch); External Reference Tables (Di Branch) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

2
In the "Timeout" area, specify a value for each item.
Setting item
Use timeout
Setting time
Important
• Normally the "Use timeout" check box should be selected. Unchecking the [Use timeout] checkbox may cause the
measurement flow to become stuck in an infinite loop when measurements are started depending on the input
condition branching processing settings.
• If using input condition branching within the block for the parallelization task in the measurement flow, set it up so
that branching occurs only within the relevant block for the parallelization task. Attempting to introduce branching
across blocks for the parallelization task may cause the timout function to stop working even with the [Use
timeout] checkbox checked.

Measurement Results for Which Output Is Possible (DI Branch)

The following values can be output using processing items related to results output. It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judge
DI input No.
Unit No

External Reference Tables (DI Branch)

No.
0
Judge
5
DI input No.
6
Unit No
Destination Unit No. 0 -
120 to151
Destination Unit No. 31
200
Timeout
201
Timeout time [s]
840
DI Branch
Setting value
[Factory default]
• Unchecked
• [Checked]
1 to 3600 [60]
Character string
JG
Judgement result
DI
Number (decimal) corresponding to DI input (00000 - 11111)
BU
Unit number at destination corresponding to DI input
Data name
Set/Get
Get
Get
Get
Set/Get
Set/Get
Set/Get
Click on the [Use timeout] checkbox to turn it ON if you
want the input condition branching processing to time
out after a set amount of time passes.
This can be set when the "Use timeout"checkbox is
selected.
Set the length of time until the measurement process
times out on the selected processing unit in seconds.
When the measurement process for this processing unit
is executed, a timeout occurs once the amount of time
that passes since the start of the measurement exceeds
the set [Setting time]. If a timeout occurs to disrupt the
measurement process, the judgement results in NG.
Description
Data range
0: No judgement (unmeasured)
1: Judgement result OK
-1: Judgement result NG
Number (decimal) corresponding to DI input (00000 - 11111)
Unit number at destination corresponding to DI input
-1: End processing
0 to 9999: Unit number
0: Not used
1: Used
1 to 3600
FH/FZ5 Processing Item Function Reference Manual