Data Logging
This is used to save measurement data in storage or USB memory.
Used in the Following Case
• When performing analysis using measurement data
Logging is performed for measurement results and these are read into an external
device such as a PC.
Example: Analysis using spreadsheet program statistical processing
Important
• If you prefer to use the Data Logging processing item, click [System settings] - [Other] - [Logging setting] - [Data Logging]
and configure the logging conditions.
• Insert data logging as close to the end of the flow as possible. If "Only NG" is selected in logging timing conditions and an
NG occurs after the data logging processing unit, it will not be logged.
• Setting data logging settings to save [Image logging] makes simultaneous confirmation of measurement data and image
data convenient.
Reference: "Chapter 3 Performing Test Measurement/Starting Operation - Useful Functions for Operation - Logging
Measurement Values and Measurement Images - Setting Logging Conditions [Logging Setting]" in the "Vision System
FH/FZ5 Series User's Manual (Z365)"
FH/FZ5 Processing Item Function Reference Manual
4