Key Points for Test Measurement and Adjustment (Statistics)

The following content is displayed in the "Detail result" area as text.
Displayed items
Judge
Calculated time
Statistical result 0
Statistical result 1
Statistical result 2
Statistical result 3
Statistical result 4
Statistical result 5
Statistical result 6
Statistical result 7
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are false
State
Not all data is included in
the calculation
The measurement result
remains 0.0
When the graph displays are false
State
A graph showing a flat line
appears even when the
value is changing.
FH/FZ5 Processing Item Function Reference Manual
Judgement result
Number of measurements performed
Statistical processing result of data 0
Statistical processing result of data 1
Statistical processing result of data 2
Statistical processing result of data 3
Statistical processing result of data 4
Statistical processing result of data 5
Statistical processing result of data 6
Statistical processing result of data 7
Parameter to be adjusted
Data display
Statistical parameter
Parameter to be adjusted
Data display
Description
Troubleshooting
Data outside the judgement range will not be processed. If any
necessary data is outside the judgement range, set the judgement
range again.
If the calculation timing is "Only when the maximum number of
data is reached," the measurement result remains 0.0 while the
number of measurements is yet to reach the maximum number
saved. Change the calculation timing on the statistical parameter
tab to "Every time," and the measurement result will be calculated
every time.
Troubleshooting
Change the graph display range to an appropriate range. If the
initial values remain unchanged, the display range is too wide and
the graph will show a flat line. Perform measurement at least
twice, and then click the default range button on the data display
tab.
4
705
Statistics