Logging Conditions (Image Logging)

Indicate the image to perform logging for. If 4 cameras are connected, image logging is performed for 4 cameras
each time.
1
Click [Logging condition] in the Item Tab area.
2
Set the logging conditions.
Setting item
Condition
3
When "Only NG" is selected, click [...] to set up the expression.
The Setting Expression window is displayed.
4
After setting up the expression, click [OK].
The expression is confirmed.
5
Set up the judgement upper limit and the judgement lower limit for "Judgement condition".
Setting item
Judgement condition
FH/FZ5 Processing Item Function Reference Manual
Set value
[Factory default]
• [None]
No images are saved.
Saves images only if an NG occurs. If an NG occurs downstream
from the image logging processing unit, image logging is not
• Only NG
performed. Insert image logging as close to the end of the scene
as possible
• All
All measured images are saved.
Set value
[Factory default]
-999999999.9999 to 999999999.9999
Description
Description
This is a judgement condition for the
expression. Set upper and lower limits for
judging as OK.
Image Logging
4
675

Hide quick links: