Measurement Results For Which Output Is Possible (Get Unit Figure) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Measurement Results for Which Output Is Possible (Get Unit Figure)

The following values can be output using processing items related to results output. It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judge
Number of figures
Size of figures
Figure N type
(N = 0 to 9)
Figure N mode
(N = 0 to 9)
Figure N data 00 to 20
(N = 0 to 9)
FH/FZ5 Processing Item Function Reference Manual
Character string
JG
The latest processing unit judgement result
NUM
Number of figures acquired
SIZ
Size of figures acquired (number of bytes)
Type of figure N
0x0000→Undefined
0x0001→Point
0x0002→Line
0x0004→Wide line
0x0008→Rectangle
FNT
0x0010→Ellipse
0x0020→Circle
0x0040→Wide circle
0x0080→Arc
0x0100→Wide arc
0x0200→Polygon
Set to 0 if no figures are acquired.
Figure N drawing mode
FNM
0: OR 1: NOT
Set to 0 if no figures are acquired.
Data 0 to 20 of figure N
• For points
0: X coordinate
1: Y coordinate
• For lines
0: X coordinate for first point
1: Y coordinate for first point
2: X coordinate for second point
3: Y coordinate for second point
• For wide lines
FND 00 to FND 20
0: X coordinate for first point
1: Y coordinate for first point
2: X coordinate for second point
3: Y coordinate for second point
4: Width
• For rectangles
0: X coordinate for upper left point
1: Y coordinate for upper left point
2: X coordinate for lower right point
3: Y coordinate for lower right point
Description
Get Unit Figure