Detection Point (Shape Search II)

Specify a position in the model that should be used as the detection coordinates during measurement. Usually,
the center position of the set model is registered as the detection point. This function is used to change to any
desired position.
A detection point can be set either directly or by referencing a unit.
Note
• After changing the detection point coordinates to another position, re-registering the model will change it back to the
center coordinates of the model.
Specifying directly
Click a position on the image you want to use as a detection point, or set coordinate data for that point.
1
In the Item Tab area, click [Detection
point].
In the Display area, the current detection point
is displayed with a crosshair cursor.
2
In the "Method" area, select "Numerical".
3
Click the position to be set as the detection point.
Note
• Displaying the image enlarged makes this clicking easier.
Reference:
FH/FZ5 Series User's Manual (Z365)"
4
Make fine adjustments using numeric
value inputs or the arrow buttons as
required.
Referencing a unit
Set a detection point by referencing a detection point unit with registered X coordinate, Y coordinate and angle
data.
1
In the Item Tab area, click [Detection point].
In the Display area, the current detection point is displayed with a crosshair cursor.
2
In the "Method" area, select "Unit".
3
In the scene in the "Unit" area, select a
detection point unit.
4
Perform the next measurement, and the detection point will be displayed.
160
Shape Search II
"Appendixes Basic Knowledge about Operations Using the Zoom Function" in the "Vision System
FH/FZ5 Processing Item Function Reference Manual