Advertisement

5
Set the reference angle with a numeric value.
6
To remeasure on the displayed image
and set the reference, click the [Measure
ref.] button. To update the reference
angle at the time of reference
measurement, place a check at "Update
the angle when measure ref.".
7
To use data before position
compensation for the reference setting
coordinates, place a check at "Use point
coordinate before scroll".
Referencing a unit
Set a reference by referencing a detection point unit with registered X coordinate, Y coordinate and angle data.
1
In the Item Tab area, click [Ref. setting].
In the display area, the current reference position will be displayed as the crosshair cursor.
2
In the "Method" area, select "Unit".
3
In the scene in the "Unit" area, select a
detection point unit.
4
Perform the next measurement, and the reference will be displayed.
FH/FZ5 Processing Item Function Reference Manual
2
125