Changing Model Parameters
Model parameter values can be changed as needed to address unstable measurement results or to increase the
processing speed. Normally, the factory default value will be used.
After changing a setting, re-register the model.
1
In the "Model parameter" area, set each
item.
Setting item
Rotation
Angle range
Skipping
angle
Smart mode
Stab.
Prec.
Changing Sub-model parameter
Set the "Sensitive model setting" as necessary.
1
Click [Sensitive model setting] in the model parameter.
2
Set up the Sub-model parameter.
FH/FZ5 Processing Item Function Reference Manual
Set value
[Factory default]
• Checked
When the measurement object is rotating, place a check at
• [Unchecked]
"Rotation" check box and specify how many degrees the model
[-180 to 180]
created rotates each time and through what range of angles. A
smaller skipping angle increases stability, but slows down the
1 to 30
processing. The normal direction is clockwise.
[5]
Checking the "Smart mode" option enables a high-speed rotation
• [Checked]
search. However, the stability may be lowered when the model
• Unchecked
shape aspect ratio is large or when the NOT mask is used.
1 to 15
Specify which is to have priority, measurement stability or speed.
[The default value
If lowering stability does not speed up processing, it is likely that
depend on the
many candidates have been detected. In this case, specify a
connected camera.
larger value for "Candidate level" or "Stab."
9 or 12]
1 to 3
Specify which is to have priority, measurement positional
[2]
precision or speed.