Output Parameters (Circular Scan Edge Width)

Specify how to treat the coordinates to be output to the external device as measurement results. This item can
be changed if necessary. Normally, the factory default value will be used.
Important
• After setting up the measurement parameters, changing the output parameters will cause measurement results to vary
accordingly. If the output parameters have been changed, re-specify the measurement, too.
1
Click [Output parameter] in the Item Tab area.
2
Specify each of the following items.
Setting item
Calibration
Reflect to overall
judgement

Key Points for Test Measurement and Adjustment (Circular Scan Edge Width)

The following contents can be displayed as text in the "Detail result" area.
Displayed items
Judge
Edge width Max.
Edge width Min.
Edge width Ave.
Lost width count
The image specified in the Sub-image number in image display setting is displayed in the Image Display area.
Sub image number.
0
1
Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are unstable
Parameter to be adjusted
Measurement
FH/FZ5 Processing Item Function Reference Manual
Set value
[Factory default]
Select whether to reflect the calibration in the values output to the
• [OFF]
external device as measurement results.
• ON
ON: Output the coordinates converted into actual dimensions.
OFF: Output the camera coordinate values.
• [ON]
Enables choosing whether or not the judgment results of this processing
• OFF
unit is reflected in the scene overall judgment.
Judgement result
The maximum value of edge width
The minimum value of edge width
The average value of all the edge width
The number of the scanned areas for which the detection of width failed
Explanation of image to be displayed
Measurement image
Scan region
If the color of the edges to be detected is decided, specify the color with [Edge color]. If results
are not stable even with the color specified, specify a larger value for the color variance range.
If noise is detected as an edge, specify larger values for "Noise level" and "Noise width".
Description