Measurement Results For Which Output Is Possible (Fine Matching) - Omron FH-3 Series Reference Manual

Vision sensor fh/fz5 series
Hide thumbs Also See for FH-3 Series:
Table of Contents

Advertisement

Key Points for Adjustment
Select the adjustment method referring to the following points.
When the measurement results are unstable
When non-existent defects are detected around the boundary
Parameter to be adjusted
Model
Measurement
When noise is detected as defects/defects cannot be detected
Parameter to be adjusted
Diff. image disp.
Measurement object near plain area
Parameter to be adjusted
Diff. image disp.
When the processing speed is slow
Parameter to be adjusted
Model
Measurement

Measurement Results for Which Output Is Possible (Fine Matching)

The following values can be output using processing items related to results output. It is also possible to
reference measurement values from expressions and other processing units.
Measurement items
Judgement
Quantity
Area
Defect position
Defect position
388
Fine Matching
Uncheck "Boundary inspection".
Set "Labeling" as the "Inspection".
Adjust "Difference".
Uncheck "Normalization".
Uncheck "Boundary inspection".
Set "Labeling" as the "Inspection".
Character string
JG
Judgement result
DA
Number of labeling
AR
Area
X
X coordinate of center of gravity position of measured defects
Y
Y coordinate of center of gravity position of measured defects
Remedy
Remedy
Remedy
Remedy
Description
FH/FZ5 Processing Item Function Reference Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents