Inputting and Setting Values (Value Setting)
Set calibration data directly with numerical values.
1
In the Item Tab area, click [Calibration].
2
In the "Calibration setting" area, select
"Parameter".
3
In the "Parameter" area, specify values
for the "Coordinate", "Origin" and
"Magnification".
Setting value
Item
[Factory default]
• [Lefthand]
Coordinate
• Righthand
• [Upperleft]
Origin
• Lowerleft
• Center
Magnification 0.00001 to 9.99999 Specify the ratio of 1 pixel to the actual dimensions.
4
Click [Generate calibration parameters].
The calibration parameters will be generated.
FH/FZ5 Processing Item Function Reference Manual
Lefthand: Clockwise is forward when setting the
coordinates.
Righthand: Counter-clockwise is forward when
setting the coordinates.
Upperleft
Center
Lowerleft
Description
Lefthand
Righthand
Set where the origin of the actual
coordinates will be.
Camera Image Input FH
1
0
X
Forward
Y
Y
Forward
0
X
69