Changing the Edge Extraction Setting
Adjust the edge extraction settings when you cannot detect edges when registering a model, or when detected
edges are broken. Re-register the model after the adjustment.
1
Click [Detail setting].
2
Adjust each setting under [Edge setting].
Setting item
Mask size
Edge level: Auto
Edge level
Noise removal level
Verifying the model on the image
1
In the [Display setting] area, adjust each
setting.
Setting item
Display model image
Display input image
Display High-Prec model
image
2
Confirm the model image on display, and register as a model.
FH/FZ5 Processing Item Function Reference Manual
Setting value
[Factory default]
• [3 × 3]
Select the range of pixels to use for edge detection. Select a
• 5 × 5
large size when the brightness varies greatly among pixels.
• 7 × 7
Select this check box to adjust [Edge level] automatically. If
• [Checked]
edges are not detected under the auto settings, clear this
• Unchecked
check box and adjust value of [Edge level].
This setting is enabled when the [Auto] check box is cleared in
the [Edge setting] area. Set the lower limit of edge level to
recognize as edge. Edges are recognized when their edge
0 to 1024
level is above this value. The smaller the value, the easier it is
to find edges. The larger the value, the less noise will affect
finding edges.
Specify the upper limit of noise level to eliminate. Noise whose
noise level is below this value will be eliminated.
0 to 100
In the noise removal process, edges are connected and
[0]
divided into a set of groups of line segments, and then these
line segments are removed one by one from shorter segments.
Setting a larger value removes larger noise.
Setting value
[Factory default]
• [Checked]
Select this check box to display and confirm the model image.
• Unchecked
This check box is available when the [Create image] check box
• [Checked]
is selected in the [Input type] area. Select this check box to
• Unchecked
check the captured image while also the created image is
displayed.
Select this check box to display the high precision model which
• Checked
is used when the [High-Prec.] check box is selected in the
• [Unchecked]
Measurement tab page.
Description
Description
Shape Search III
2