Double-click [GOT] of the PLC side I/F to display
[PLC side I/F Detailed Setting of GOT].
7.
Check-mark [C24] in [PLC side I/F Detailed Setting of
GOT].
8.
The screen returns to [Transfer Setup Connection1].
Click [Connection Test] to check if GX Works2 has
been connected to the QCPU (Q mode).
(3) Connecting the GOT and PLC in Ethernet
connection
(a) Connecting to QCPU (Q mode)
1.
Click the Connection Destination view
[Connection Destination]
name)] in the Navigation window of GX Works2.
2.
The [Transfer Setup Connection1] is displayed.
3.
Set the [Transfer Setup Connection1]:
PC side I/F
PLC side I/F
Other Station Setting
4.
Double-click [Serial USB] of the PC side I/F to display
[PC side I/F Serial Setting].
5.
Check-mark either of the following in [PC side I/F
Serial Setting].
When connecting the GOT and PC with serial
Mark the [RS-232C] checkbox.
When connecting the GOT and PC with USB
Mark the [USB] checkbox.
23. FA TRANSPARENT FUNCTION
23.6 Personal Computer Side Setting
[(Connection target data
: Serial USB
: GOT
: Other Station (Single
Network)
23 - 59
17
18
19
20
21
22
23