Mitsubishi Electric GT1685 Connection Manual page 104

Got1000 series
Table of Contents

Advertisement

2.5 MELSEC-QnA/Q/QS, MELDAS C6 *
The device ranges that can be set when selecting
[MELSEC-QnA/Q/QS, MELDAS C6*]
type are as follows.
*6*7*11
Device name
Input (X)
Output (Y)
*8
Internal relay (M)
Latch relay (L)
Annunciator (F)
Link relay (B)
Contact (TT)
*8
Timer
Coil (TC)
Contact (CT)
*8
Counter
Coil (CC)
Special relay (SM)
Contact (SS)
Retentive
*8
timer
Coil (SC)
Step relay (S)
Link special relay (SB)
The bit specification of the
word device
(except Timer, Counter,
Retentive timer, Index
register)
*8
Data register (D)
Special data register (SD)
Link register (W)
*8
Timer (current value) (TN)
Counter (current value)
*8
(CN)
Retentive timer
*8
(current value) (SN)
Link special register (SW)
*1*2
File register (R)
Extension
Block
file register
Device
*1*9*10
(ER)
Extension file register
*1*3*9*10
(ZR)
Index register (Z)
Buffer memory
(Intelligent function module)
*4*9*10
(BM)
Buffer memory
(Intelligent function module)
*4*9*10
(G)
*9*10
Ww
*9*10
Wr
The word specification of
*5*9
the bit device
(except Timer, Counter,
Retentive timer)
2 - 12
2. DEVICE RANGE THAT CAN BE SET
2.5 MELSEC-QnA/Q/QS, MELDAS C6 *
*12
as the controller
Device No.
Setting range
representation
X0
to
X3FFF
Hexadecimal
Y0
to
Y3FFF
M0
to
M32767
Decimal
L0
to
L32767
F0
to
F32767
B0
to
B7FFF
Hexadecimal
TT0
to
TT32767
TC0
to
TC32767
CT0
to
CT32767
CC0
to
CC32767
Decimal
SM0
to
SM2047
SS0
to
SS32767
SC0
to
SC32767
S0
to
S32767
SB0
to
SB7FFF
Hexadecimal
Setting range of each
word device
D0
to
D32767
Decimal
SD0
to
SD2047
W0
to
W7FFF
Hexadecimal
TN0
to
TN32767
CN0
to
CN32767
Decimal
SN0
to
SN32767
SW0
to
SW7FFF
Hexadecimal
R0
to
R32767
0
to
255
R0
to
R32767
ZR0
to
ZR1042431
Decimal
Z0
to
Z15
BM0
to
BM32767
G0
to
G65535
Ww0 to
Ww1FFF
Hexadecimal
Wr0
to
Wr1FFF
Setting range of each bit
devices
*1
*2
*3
*4
*5
*6
*7
*8
*9
*10
*11
*12
Do not set a file register by GT Designer3 when executing
multiple programs with the file of the file register set at [Use
the same file name as the program] by the PLC parameter of
GX Developer.(Except MELSEC-QnA)
Otherwise, read/write at GOT will be erroneous.
Available for file register of block No. switched with the RSET
instruction.
Available for file register of block No. of file name switched
with the QDRSET instruction.
Only the intelligent function module on the station connected
to GOT can be specified.
Set within the address range of the buffer memory existing in
the target intelligent function module.
The device No. must be set in multiples of 16.
When monitoring MELDAS C6/64, if a word device outside
the range is set, the value becomes indefinite.
When a bit device outside the range is set, the object may
not be displayed or the set function may fail to operate.
Check the set device using the device list of GT Designer3.
Devices used by the MELDAS C6/64 system cannot be
used.
Do not use local devices set in the MELSEC-Q system.
Otherwise, normal monitoring is not performed.
This is not supported by GT10.
This cannot be monitored when in GOT multi-drop
connection.
Only reading is possible from QS001CPU.
For GT14, GT11 and GT10, the controller type is as follows.
• GT14, GT11: MELSEC-QnA/Q, MELDAS C6 *
• GT10: MELSEC-QnA/Q

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents