(2) When connecting the GOT and PLC in direct CPU connection
The following shows the software and the accessible PLC CPUs.
PLC CPU
FX5U, FX5UC
QCPU (Q mode)
*14
LCPU
QCPU (A mode), QnA/ACPU
FXCPU
Motion controller CPU (Q Series)
Motion controller CPU (A Series)
MELSERVO(MR-J3-B)
MELSERVO(MR-J4-B)
FREQROL A700/F700/E700/D700 Series
Sensorless servo (FREQROL E700EX)
Robot controller (CRnQ-700)
*1
MR Configurator (MRZJW3-SETUP221E) Version B1 or later is required to use the FA transparent function.
*2
FR Configurator(FR-SW2-SETUP-WJ) Ver.1.02 or later is required to use the FA transparent function when connecting the A700/
F700 series to the GOT.
FR Configurator(FR-SW3-SETUP-WJ) Ver.2.00 or later is required to use the FA transparent function when connecting the E700
series to the GOT.
FR Configurator(FR-SW3-SETUP-WJ) Ver.3.10 or later is required to use the FA transparent function when connecting the F700
series to the GOT.
*3
PX Developer Version 1.09K or later is required to use the FA transparent function.
PX Developer Version 1.18U or later is required to use the FA transparent function when connecting the Q02PHCPU or
Q06PHCPU to the GOT.
*4
Use GX Developer Version 8.30G or later combined with the following GX Configurator version or later to use the FA transparent
function.
*5
The RS-232/USB conversion adaptor (GT10-RS2TUSB-5S) is not applicable to FX-PCS/WIN.
*6
FX Configurator-FP Version 1.30 or later is required to use the FA transparent function.
*7
RT ToolBox2 Version 1.1 or later is required to use the FA transparent function.
*8
GX Configurator-QP Version2.32J or later is required to use the FA transparent function.
*9
MT Works2 Version 1.00A or later is required to use the FA transparent function.
*10
MELSOFT Navigator Version 1.04E or later is required to use the FA transparent function.
*11
GX Works2 Version 1.03D or later is required to use the FA transparent function.
23 - 4
23. FA TRANSPARENT FUNCTION
23.2 Compatible Software
GX Works3
MELSOFT Navigator
GX Developer
GX Works2
PX Developer
GX Configurator
GX Configurator-QP
MX Component
MELSOFT Navigator
GX Developer
MX Component
GX Developer
MX Component
MELSOFT Navigator
GX Developer
GX Works2
FX-PCS/WIN
FX Configurator-FP
FX3U-ENET-L Configuration tool
MX Component
MELSOFT Navigator
MT Developer
SW6RN-GSV13P,
SW6RN-GSV54P,
MT Works2
MR Configurator
GX Developer
SW3RN-GSV13P,
SW3RN-GSV51P
MX Component
*21
MR Configurator
*21
MR Configurator2
FR Configurator
FR Configurator
RT ToolBox2
GX Configurator-AD
: Version 2.03D pr later,
GX Configurator-SC
: Version 2.10L or later,
GX Configurator-TI
: Version 1.22Y or later,
GX Configurator-AS
: Version 1.20W or later, GX Configurator-FL
GX Configurator-PT
: Version 1.20W or later
*25
*26
,
MX Component
,
*10
*11
*3
*4
-AD/DA/SC/CT/TI/TC/AS/FL/PT
*8
*16
*17
,
MX Sheet
*15
*12
*13
GX Works2
,
*16
*17
,
MX Sheet
,
*16
*17
,
MX Sheet
*10
*11
*5
*6
*16
*17
,
MX Sheet
*10
SW6RN-GSV22P,
SW6RN-DOSCP,
*9
*1
*22
,
MX Component
,
SW3RN-GSV22P,
*16
*17
,
MX Sheet
*1
*18
,
MR Configurator2
*20
*2
*24
*7
GX Configurator-DA
GX Configurator-CT
GX Configurator-TC
Software
*27
MX Sheet
GX Logviewer
CPU Module Logging Configuration Tool
SW6RN-GSV43P,
SW6RN-SNETP (for user API)
*23
MX Sheet
SW3RN-GSV43P,
: Version 2.04E or later
: Version 1.23Zor later
: Version 1.21X or later
: Version 1.21X or later
*19