Device
name
ST14
Bus voltage
ST15
Load-side cumulative feedback pulses
ST16
Load-side droop pulses
Load-side encoder information 1/Z-phase
ST17
counter
ST18
Load-side encoder information 2
ST19 to
For manufacturer setting
ST21
ST22
Temperature of servo motor thermistor
Servo motor-side cumulative feedback
ST23
pulses (before gear)
ST24
Electrical angle
ST25 to
For manufacturer setting
ST29
Servo motor-side/load-side position
ST30
deviation
ST31
Servo motor-side/load-side speed deviation
ST32
Internal temperature of encoder
ST33
Settling time
ST34
Oscillation detection frequency
ST35
Number of tough drive operations
ST36 to
For manufacturer setting
ST39
ST40
Unit power consumption
ST41
Unit total power consumption
ST42
Current position
ST43
Command position
ST44
Command remaining distance
Point table No./Program No./Station position
ST45
No.
ST46
Step No.
ST47
Analog override voltage
ST48
Override level
(o) Alarm (compatible with MELSERVO-J3-*A)
Device
name
AL0
Current alarm number
AL1
Detailed data of current alarms
Servo status when alarm occurs cumulative
AL11
feedback pulses
Servo status when alarm occurs Servo motor
AL12
speed
AL13
Servo status when alarm occurs droop pulses
Servo status when alarm occurs cumulative
AL14
command pulses
Servo status when alarm occurs command
AL15
pulse frequency
Servo status (alarm) analog speed command
AL16
voltage/limit voltage
Servo status (alarm) analog torque command
AL17
voltage/limit voltage
Servo status when alarm occurs regenerative
AL18
load ratio
Servo status when alarm occurs effective load
AL19
ratio
AL20
Servo status when alarm occurs peak load ratio
Servo status when alarm occurs instantaneous
AL21
torque
16 - 54
16. SERVO AMPLIFIER CONNECTION
16.6 Device Range that Can Be Set
Item
Symbol
Item
Symbol
Device
name
Servo status (alarm) Within one-revolution
AL22
position(1 pulse unit)
AL23
Servo status when alarm occurs ABS counter
AL24
Servo status(alarm) load inertia moment ratio
AL25
Servo status when alarm occurs bus voltage
Alarm number from Alarm History most recent
AL200
alarm
Alarm number from Alarm History first alarm in
AL201
past
Alarm number from Alarm History second alarm
AL202
in past
Alarm number from Alarm History third alarm in
AL203
past
Alarm number from Alarm History fourth alarm
AL204
in past
Alarm number from Alarm History fifth alarm in
AL205
past
Alarm occurrence time in alarm history most
AL210
recent alarm
Alarm occurrence time in alarm history first
AL211
alarm in past
Alarm occurrence time in alarm history second
AL212
alarm in past
Alarm occurrence time in alarm history third
AL213
alarm in past
Alarm occurrence time in alarm history fourth
AL214
alarm in past
Alarm occurrence time in alarm history fifth
AL215
alarm in past
Detailed alarm from Alarm History most recent
AL230
alarm
Detailed alarm from Alarm History first alarm in
AL231
past
Detailed alarm from Alarm History second alarm
AL232
in past
Detailed alarm from Alarm History third alarm in
AL233
past
Detailed alarm from Alarm History fourth alarm
AL234
in past
Detailed alarm from Alarm History fifth alarm in
AL235
past
(p) Alarm (compatible with MELSERVO-J4-*A)
Device
name
ALM0
Current alarm number
ALM1
Detailed data of current alarms
Servo status when alarm occurs cumulative
ALM11
feedback pulses
Servo status when alarm occurs Servo motor
ALM12
speed
ALM13
Servo status when alarm occurs droop pulses
Servo status when alarm occurs cumulative
ALM14
command pulses
Servo status when alarm occurs command
ALM15
pulse frequency
Servo status (alarm) analog speed command
ALM16
voltage/limit voltage
Servo status (alarm) analog torque command
ALM17
voltage/limit voltage
Item
Symbol
Item
Symbol