18.5 CNC Side Settings

18.5.1 MELSECNET/10 connection

Parameter setting
Set parameters related to MELSECNET/10 with
MELSEC's peripheral devices in the same way as
parameter setting of MELSEC CPU, and write them on
CNC by Personal computer. However, in the case of
using the default parameters or not requiring separate
settings due to normal stations, it is not necessary to
set the network
(1) Control Station Parameter
If you wish to place the control station in CNC and set
the common parameters, set the network parameters
by peripheral device and write them on CNC. An
example of parameter setting by GPPW is as follows.
Set the first I/O No. as follows according to the
expansion slot to which the unit is inserted.
(a) Start I/O No.
Slot
Start I/O No.
EXT1
0200
EXT2
0280
(b) Example of GX Developer setting
For details of the parameter setting, refer to the
following.
C6/C64/C64T NETWORK INSTRUCTION
MANUAL BNP-B2373
(2) Normal Station Parameter
As for normal stations, it is not necessary to set
parameters unless separate settings are required.
The refresh parameters are set and written as required.
In this case, the parameter setting of the first I/O No. is
the same as in the case of the control station.
18 - 16
18. CNC CONNECTION
18.5 CNC Side Settings
EXT1
EXT2