Mitsubishi Electric GT1685 Connection Manual page 295

Got1000 series
Table of Contents

Advertisement

PLC
Ethernet module
Model name
*4*5
MELSEC-L
LJ71E71-100
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
A cross cable is available for connecting the GOT to the Ethernet module.
*2
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
For the system configuration of the Ethernet module, refer to the following manuals.
*5
Select one of the following [Controller Type] in [Ethernet] of GT Designer3.
• Ethernet module (MELSEC iQ-R Series): RJ71EN71
• Ethernet module (Q Series): QJ71E71
• Ethernet module (QnA Series): AJ71QE71
• Ethernet module (A Series): AJ71QE71
For [Ethernet] of GT Designer3, refer to the following.
*6
When using the peripheral I/F of Q170MCPU, Q17nDCPU-S1 or MR-MQ100, refer to the following.
*7
In case of RJ71EN71, the number of connectable GOTs for one network is 119 units (at most).
Other than RJ71EN71, the number of connectable GOTs for one network is 63 units (at most).
*8
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
*9
GT14 cannot be connected with MELSEC-QS.
Connection cable
Communication
Cable model
type
Twisted pair cable
• 10BASE-T
Shielded twisted pair
cable (STP) or unshielded
twisted pair cable (UTP):
Ethernet
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair
cable (STP):
Category 5 and 5e
GT16 User's Manual (Hardware)
Q Corresponding Ethernet Interface Module User's Manual (Basic)
For QnA Ethernet Interface Module User's Manual
For A Ethernet Interface Module User's Manual
8.3.3 Ethernet setting
8.2.5 Connecting to PERIPHERAL I/F (Built-in Ethernet port Motion Controller CPU)
*1
GOT
Maximum
segment
Option device
*3
length
- (Built into GOT)
100m
GT15-J71E71-100
8. ETHERNET CONNECTION
8.2 System Configuration
1
Number of
connectable
Model
equipment
*2
*8
*7
128 GOTs
(recommended to
2
16 units or less)
3
4
5
6
7
8
8 - 9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents