Item
Description
Monitor
Set the monitor speed of the GOT.
Speed
This setting is not valid in all systems.
(GT16 only)
(Default: Normal)
*1
This is effective when collecting a large data on other than
the monitor screen (logging, recipe function, etc.). However,
when connecting to Q00J/Q00/Q01CPU, the sequence scan
time may be influenced. If you want to avoid the influence on
the sequence scan time, do not set "High".
(High performance is hardly affected)
*2
Set this item if you want to avoid the influence on the
sequence scan time further than the "Normal" setting when
connecting to Q00J/Q00/Q01CPU. However, the monitor
speed may be reduced.
*3
Refer to the following POINT.
POINT
POINT
POINT
Setting [Format]
This setting is required for replacement of F900 series
with GOT1000 series.
(1) To change the communication settings of the
serial communication module which is connected
to F900, set as follows.
The value of Transmission Speed can be set to
115200bps.
(a) [Intelligent function module switch setting] of
PLC
Switch No.
Switch 1
Switch 2
Switch 3
Switch 4
Switch 5
7.5 PLC Side Setting
(b) GOT communication settings
Format
1
(2) To maintain the communication settings of the
serial communication module which is connected
to F900, set the communication setting of the GOT
as follows.
The value of Transmission Speed remains
38400bps.
Format
2
7 - 22
7. COMPUTER LINK CONNECTION
7.4 GOT Side Settings
Range
*1
High
Normal
*2
Low
CH1 side
CH2 side
0000
-
H
0000
-
H
-
0000
H
-
0000
H
0000
0000
H
H
Transmission Speed
38400bps
(2) AJ71QC24, MELDAS C6*
Item
Description
Set this item when change the
Transmission
transmission speed used for
Speed
communication with the connected
equipment. (Default: 19200bps)
Set this item when change the data
length used for communication with the
Data Bit
connected equipment.
(Default: 8bit)
Specify the stop bit length for
Stop Bit
communications.
(Default: 1bit)
Specify whether or not to perform a
parity check, and how it is performed
Parity
during communication.
(Default: Odd)
Set the number of retries to be
performed when a communication
timeout occurs. When receiving no
Retry
response after retries, the
communication times out.
(Default: 0time)
Set the time period for a communication
Timeout Time
to time out. (Default: 3sec)
Set this item to adjust the transmission
Delay Time
timing of the communication request
from the GOT. (Default: 0ms)
Range
4800bps,
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
8bit (fixed)
1bit (fixed)
Odd (fixed)
0 to 5times
3 to 30sec
0 to 300 (ms)