Connecting To Ethernet Module (Q/L Series) - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

Checking communication state of Connecting
to Built-in Ethernet port CPU
(1) When using the Command Prompt of Windows
Execute a Ping command at the Command Prompt of
Windows
.
(a) When normal communication
C:\>Ping 192.168.0.1
Reply from 192.168.0.1: bytes=32 time
<10ms TTL=32
(b) When abnormal communication
C:\>Ping 192.168.0.1
Request timed out.
(2) When abnormal communication
At abnormal communication, check the followings and
execute the Ping command again.
• Cable connecting condition
• Confirmation of switch and network parameter setting
• Operation state of PLC CPU (faulty or not)
• The IP address of Built-in Ethernet port CPU specified
in the ping command
POINT
POINT
POINT
Ethernet diagnostics of GX Developer
Ethernet diagnostics of GX Developer is available to a
Ping test from the PLC.
For details of Ethernet diagnostics of GX Developer,
refer to the following manual.
QCPU User's Manual (Hardware Design,
Maintenance and Inspection)
MELSEC-L CPU Module User's Manual
(Hardware Design, Maintenance and
Inspection)
8.4.7
Connecting to Ethernet
module (Q/L Series)
.
This section describes the settings of the GOT and
Ethernet module (Q Series) in the following case of the
system configuration.
POINT
POINT
POINT
Ethernet module (Q/L Series)
For details of the Ethernet module (Q/L Series), refer
to the following manual.
Q Corresponding Ethernet Interface Module
User's Manual (Basic)
MELSEC-L Ethernet Interface Module User's
Manual (Basic)
System configuration (for Q series)
■ [Network parameter] of GX Developer
*1
The Ethernet module is mounted on the base unit slot 0.
The Start I/O No. of the Ethernet module is set to "0".
POINT
POINT
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of
the Ethernet module is set to "70".
8. ETHERNET CONNECTION
[Controller Setting] and [Ethernet] of GT
Designer3
<GOT> (The settings other than the
following are set to the default)
Network No.
PLC No.
IP address
Port No.
Communication format : UDP (fixed)
*1
<Ethernet module> (The settings other than the
following are set to the default)
Network No.
: 1
PLC No.
: 2
IP address
: 192.168.0.19
Port No.
: 5001
Communication format
: UDP(fixed)
8.4 PLC Side Setting
1
2
3
4
: 1
: 1
: 192.168.0.18
: 5001
5
6
7
8
8 - 35