Mitsubishi Electric GT1685 Connection Manual page 386

Got1000 series
Table of Contents

Advertisement

10.4.2 Connecting to MELSECNET/
10 network module (QnA
Series)
This section describes the settings of the GOT and
MELSECNET/10 network module (QnA series) in the
following case of system configuration.
In this section, the network parameter (common
parameter) of GX Developer is taken as an example to
provide explanations.
POINT
POINT
POINT
MELSECNET/10 network module (QnA Series)
For details of the MELSECNET/10 network module
(QnA Series), refer to the following manual.
For QnA/Q4AR MELSECNET/10 Network
System Reference Manual
System configuration
■ [Controller Setting] of GT Designer3
■ Setting of the MELSECNET/10 communication unit
MELSECNET/10 (PLC to PLC network)
<MELSECNET/10 network module> *1
(Use the default value for settings other than the following.)
Station No.
Mode
Network type
Network No.
Total stations
Network range assignment: B0000
■ Switch setting of MELSECNET/10 network module
■ [Network parameter] of GX Developer
*1
The MELSECNET/10 network module is mounted at slot 0 of
the base unit.
The start I/O No. of the MELSECNET/10 network module is
set at "0".
10 - 18
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
10.4 PLC Side Setting
<GOT>
(Use the default value for settings other
than the following.)
: 2
: Online
: 1
W0100
to W01FF
H
: 1
: Online
: MNET/10 (Control station)
: 1
: 2
to B00FF
H
H
W0000
to W00FF
H
H
Switch setting of MELSECNET/10 network
module
Set for each setting switch.
AJ71QLP21
A
J71QLP21
RUN -
- POWER
PC -
- MNG
REMOTE -
- S.MNG
10
1
DUAL -
- D.LINK
SW.E -
- T.PASS
M/S.E -
-
100
PRM.E -
- CPUR/W
CRC -
- CRC
OVER -
- OVER
E
E
AB.IF -
- AB.IF
R
R
TIME -
- TIME
R
DATA -
- DATA
R
O
UNDER -
- UNDER
O
LOOP -
- LOOP
R
R
SD -
- SD
RD -
- RD
F.LOOP
R.LOOP
NETWORK NO.
X100
(1)
X10
X1
(2)
GROUP NO.
STATION NO.
X10
(3)
X1
(5)
MODE
0: ONLINE(A.R)
2: OFFLINE
OFF
ON
OFF
ON SW
PC
REMOTE
1
N.ST
MNG
2
PRM
D.PRM
3
(6)
4
STATION SIZE
(8.16.32.64)
5
LB/LW SIZE
6
(2.4.6.8K)
7
8
FRONT SIDE
IN
OUT
A1SJ71QLP21
A1SJ71QLP21
RUN
PW
CRC
‚d
MNG
PC
OVER
‚q
S.MNG
REM.
AB. IF
‚q
DUAL
SWE.
TIME
‚n
D.LINK
DATA
‚q
M/S.E.
T.PASS
PRM E.
UNDER
F.E.
R.E.
SD
CPU R/W
RD
H
NETWORK
NO.
DISPLAY
X100
L
R
(F.L)
(R.L.)
(1)
X10
X1
SW
OFF
ON
1
PC
REM.
2
N.ST
MNG
(2)
3
PRM
D.PRM
GR.NO.
4
ST,SIZE
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
2,4,6,8k
(3)
8
X1
OFF ON
SW
C
1
(5)
MODE
2
3
MODE
4
0 : ONLINE(A.R)
5
2 : OFFLINE
6
FRONT SIDE
7
8
IN
OUT
A1SJ71QLP21
A1SJ71QBR11
A1SJ71QBR11
RUN
PW
CRC
MNG
PC
OVER
S.MNG
REM.
AB. IF
SWE.
TIME
D.LINK
M/S.E.
DATA
T.PASS
PRM E.
UNDER
SD
CPU R/W
RD
NETWORK
NO.
DISPLAY
X100
L
(F.L)
(R.L.)
(1)
X10
X1
SW
OFF
1
PC
2
N.ST
(2)
3
PRM
D.PRM
GR.NO.
4
ST,SIZE
5
8,16,32,64
ST.NO.
6
LB/LW SIZE
X10
7
2,4,6,8k
(3)
8
X1
OFF ON
(5)
C
MODE
MODE
0 : ONLINE (A.R)
2 : OFFLINE
A1SJ71QBR11
AJ71QLP21S
AJ71QBR11
A
A
J71QLP21S
J71QBR11
RUN -
- POWER
RUN -
PC -
- MNG
PC -
REMOTE -
- S.MNG
REMOTE -
10
1
10
DUAL -
- D.LINK
SW.E -
- T.PASS
SW.E -
M/S.E -
- EX.POWER
M/S.E -
100
100
PRM.E -
- CPUR/W
PRM.E -
CRC -
- CRC
CRC -
OVER -
- OVER
OVER -
E
E
E
AB.IF -
- AB.IF
AB.IF -
R
R
R
TIME -
- TIME
TIME -
R
DATA -
- DATA
R
R
DATA -
O
UNDER -
- UNDER
O
O
UNDER -
LOOP -
- LOOP
R
R
R
SD -
- SD
SD -
RD -
- RD
RD -
F.LOOP
R.LOOP
NETWORK NO.
NETWORK NO.
X100
X100
(1)
X10
X10
X1
(2)
GROUP NO.
GROUP NO.
STATION NO.
STATION NO.
X10
X10
(3)
X1
(5)
MODE
MODE
0: ONLINE(A.R)
0: ONLINE(A.R)
2: OFFLINE
2: OFFLINE
OFF
ON
OFF
ON SW
OFF
ON
PC
REMOTE
PC
REMOTE
1
N.ST
MNG
2
N.ST
MNG
PRM
D.PRM
3
(6)
PRM
D.PRM
STATION SIZE
4
STATION SIZE
(8.16.32.64)
5
(8.16.32.64)
6
LB/LW SIZE
LB/LW SIZE
(2.4.6.8K)
7
(2.4.6.8K)
8
24V
24G
FG
FRONT SIDE
IN
OUT
A1SJ71QLP21S
A1SJ71QLP21S
RUN
MNG
EXT.P W
S.MNG
DUAL
D.LINK
T.PASS
F.E.
NETWORK
NO.
(4)
X100
(1)
X10
X1
(2)
GR.NO.
(3)
ST.NO.
X10
EXT.PW
X1
{24V
MODE
(6)
24G
MODE
0 : ONLINE(A.R)
2 : FOFFLINE
FRONT SIDE
FG
(5)
A1SJ71QLP21S
‚d
‚q
‚q
‚n
‚q
(4)
R
ON
REM.
MNG
SW
1
2
3
(6)
4
5
6
7
8
- POWER
- MNG
- S.MNG
1
- D.LINK
- T.PASS
-
- CPUR/W
(1)
X1
(2)
(3)
X1
(5)
OFF
ON SW
1
2
3
(6)
4
5
6
7
8
PW
CRC
‚d
PC
OVER
‚q
REM.
AB. IF
‚q
SWE.
TIME
‚n
M/S.E.
DATA
‚q
PRM E.
UNDER
R.E.
SD
CPU R/W
RD
DISPLAY
(4)
L
R
(F.L)
(R.L.)
SW
OFF
ON
1
PC
REM.
2
N.ST
MNG
3
PRM
D.PRM
4
ST,SIZE
5
8,16,32,64
6
LB/LW SIZE
7
2,4,6,8k
8
OFF ON
SW
C
1
2
3
(6)
4
5
6
7
8
IN
OUT

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents