(c) CC-Link configuration setting
*1
Item
Station type
*2
Exclusive station count
Reserve/invalid station
select
Intelligent buffer select
(word)
: Necessary
*1
When the [Mode] of the CC-Link module is set at [Remote
net - (Ver. 1 mode)], [Remote station points] cannot be set.
*2
Set the same setting as that of the GOT.
POINT
POINT
POINT
When changing the unit parameter
After writing unit parameters to the PLC CPU, turn the
PLC CPU OFF then back ON again, or reset the PLC
CPU.
[Controller Setting] of GT Designer3
Item
Station No.
Transmission Rate
Mode
Expanded Cyclic
Number of stations occupied
Input for Error Station
Retry
Timeout Time
Delay Time
POINT
POINT
POINT
[Controller Setting] of GT Designer3
For the setting method of [Controller Setting] of GT
Designer3, refer to the following.
13.3.1 Setting communication interface
(Communication settings)
13 - 16
13. CC-Link CONNECTION (INTELLIGENT DEVICE STATION)
13.4 PLC Side Setting
Setting
necessity at
Set value
GOT
connection
Intelligent device
station (fixed)
Exclusive station 1
No setting
(Use default value)
: As necessary
: Not necessary
Set value
1: Station No.1
0: Online 156kbps
Ver.1: Remote net (Ver.1 mode)
Single (Use default value)
1 Station
0: Clear
3times (Use default value)
3sec (Use default value)
0sec (Use default value)
13.4.2 Connecting to CC-Link module
(MELSEC iQ-R Series) with
Ver.2 compatible
This section describes the settings of the GOT and the CC-
Link module (MELSEC iQ-R Series) with Ver.2 compatible
in the following system configuration.
POINT
POINT
POINT
CC-Link module (MELSEC iQ-R Series)
For details of the CC-Link module (MELSEC iQ-R
Series), refer to the following manual.
Manuals of MELSEC iQ-R Series
System configuration
*1
<CC-Link module>
(Use the default value for the settings other than the following.)
Type
: Master station
Station No.
: Station No.0
Mode
: Remote net (Ver.2 mode)
All connect count
: 1
Transmission speed : 156kbps
■ Unit parameter setting of GX Works3
*1
The CC-Link module is mounted on the base unit slot 0.
The Start I/O No. of the CC-Link module is set to "0".
Unit parameter setting of GX Works3
(1) [Unit parameter] of GX Works3
(a) Unit parameter
Item
Station type
Mode
■ [Communication settings] of GT Designer3
<GOT>
(Use the default value for settings other
than the following.)
Station No.
: Station No.1
Expanded cyclic setting : Single
Number of
: Exclusive station 1
stations occupied
Transmission speed
: 156kbps
Setting necessity
Set value
at GOT
connection
Master station
Remote net
(Ver.2 mode)