Melsec-Q (Multi)/Q Motion - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

2.6 MELSEC-Q (Multi)/Q Motion

The device ranges that can be set when selecting
[MELSEC-Q (Multi)/Q Motion]
as follows.
Device name
Input (X)
X0
Output (Y)
Y0
*12
M0
Internal relay (M)
Latch relay (L)
L0
Annunciator (F)
F0
Link relay (B)
B0
Contact (TT)
TT0
*12
Timer
Coil (TC)
TC0
Contact (CT)
CT0
*12
Counter
Coil (CC)
CC0
*9
SM0
Special relay (SM)
Retentive
Contact (SS)
SS0
*12
timer
Coil (SC)
SC0
Step relay (S)
S0
Link special relay (SB)
SB0
The bit specification of the
word device
Setting range of each
(except Timer, Counter,
Retentive timer, Index
register)
*10*11*12
D0
Data register (D)
Special data register (SD)
SD0
Link register (W)
W0
*12
TN0
Timer (current value) (TN)
Counter (current value)
CN0
*12
(CN)
Retentive timer
SN0
*12
(current value) (SN)
Link special register (SW)
SW0
*1*2
R0
File register (R)
Extension
Block
0
file register
Device
R0
*1*7*8
(ER)
Extension file register
ZR0
*1*3*4*7*8
(ZR)
Index register (Z)
Z0
Buffer memory
(Intelligent function module)
BM0
*5*7*8
(BM)
Buffer memory
(Intelligent function module)
G0
*4*5*7*8
(G)
*7*8
Ww0 to
Ww
*7*8
Wr0
Wr
*7*8
#0
Motion device (#)
The word specification of
*6*7
Setting range of each bit
the bit device
(except Timer, Counter,
Retentive timer)
*13
as the controller type are
Device No.
Setting range
representation
to
X1FFF
Hexadecimal
to
Y1FFF
to
M32767
Decimal
to
L32767
to
F32767
to
B7FFF
Hexadecimal
to
TT32767
to
TC32767
to
CT32767
to
CC32767
Decimal
to
SM2047
to
SS32767
to
SC32767
to
S32767
to
SB7FF
Hexadecimal
word device
to
D32767
Decimal
to
SD2047
to
W7FFF
Hexadecimal
to
TN32767
to
CN32767
Decimal
to
SN32767
to
SW7FF
Hexadecimal
to
R32767
to
255
to
R32767
to
ZR1042431
Decimal
to
Z15
to
BM32767
to
G65535
Ww7FF
Hexadecimal
to
Wr7FF
to
#8191
Decimal
devices
(When using the QCPU)
* For details of *1 to *6, refer to 2.5 MELSEC-QnA/Q/QS,
MELDAS C6 *.
*7
This is not supported by GT10.
*8
This cannot be monitored when in GOT multi-drop
connection.
(When using the Q Motion)
*9
When setting special internal relay M9000 to M9255, use SM
for the device name and set the value subtracted 9000 for
the device number (0 to 255).
*10
The setting range is D9000 to D9255 when setting the
special data register.
*11
D8192 to D8999 and D9256 to D9999 are out of the valid
setting range.
(When using the QCPU/Q Motion)
*12
Do not use local devices set in the MELSEC-Q (Multi)/Q
Motion system.
Otherwise, normal monitoring is not performed.
*13
For GT10, the controller type is [MELSEC-Q(Multi)].
2. DEVICE RANGE THAT CAN BE SET
2.6 MELSEC-Q (Multi)/Q Motion
1
2
3
4
5
6
7
8
2 - 13

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents