Mitsubishi Electric GT1685 Connection Manual page 115

Got1000 series
Table of Contents

Advertisement

MELSECNET/H connection, MELSECNET/10 connection, CC-Link IE Controller Network
connection, CC-Link IE Field Network connection
POINT
POINT
POINT
Precautions for cyclic transmission
Devices that can be accessed by cyclic transmission differ according to connection type.
Connection type
MELSECNET/H
MELSECNET/10
CC-Link IE Controller Network
CC-Link IE Field Network
• The GOT is regarded as a normal station and monitors the control station and all normal stations on the
network.
When the monitoring target is a PLC CPU within a multiple CPU system, the GOT can monitor CPU No. 1 to
CPU No. 4 by specifying CPU No.
• When monitoring other networks, a CPU on another Ethernet, MELSECNET/H, MELSECNET/10, CC-Link IE
Controller Network, or CC-Link field network is accessible via the PLC CPU.(Monitoring other networks via a
motion controller CPU (MELSEC iQ-R series) is available by Ethernet only.)
However, the GOT cannot monitor the CNC C70 on other networks.
Only the RCPU, QCPU (Q mode), and QnACPU are accessible on Ethernet networks.
• When monitoring other networks in MELSECNET/10 connection, install the MELSECNET/H communication
unit on the GOT.
• To monitor other networks, setting of routing parameters is required.
For routing parameter setting, refer to the following manuals.
Routing parameter setting for the GOT
9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK)
10. MELSECNET/10 CONNECTION (PLC TO PLC NETWORK)
11. CC-Link IE CONTROLLER NETWORK CONNECTION
12. CC-Link IE FIELD NETWORK CONNECTION
Routing parameter setting for the PLC CPU (MELSECNET/H network system, MELSECNET/10 network
system)
Q Corresponding MELSECNET/H Network System Reference Manual (PLC to PLC network)
Routing parameter setting for the PLC CPU (When connecting to the CC-Link IE Controller Network)
CC-Link IE Controller Network Reference Manual
Routing parameter setting for the PLC CPU (When connecting to the CC-Link IE Field Network)
CC-Link IE Field Network Master/Local Module User's Manual
• If devices of other stations (other than devices B and W that are allocated by the network parameter) are
monitored, monitoring may not be available depending on the PLC CPU of the network system to be monitored.
■ Monitor accessible range of other stations and setting method of monitor devices Example 5:
When using MELSECNET/10 connection
Devices that can be accessed
B, W, LB, LW, SB, SW
B, W, LB, LW, SB, SW
B, W, LB, LW, SB, SW
X, Y, RX, RY, Ww, Wr, SB, SW
3. ACCESS RANGE FOR MONITORING
3.1 Access Range for Monitoring Stations on Network Systems
1
2
3
4
5
6
7
8
3 - 5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents