[Network parameter] of GX Developer
(1) Network parameter
Item
Network type
Ethernet (fixed)
Start I/O No.
*1
Network No.
Group No.
*2
Station No.
IP address
192.168.0.19
Station No.<->IP
information
(Use default value)
FTP Parameters
Router relay parameter
Routing parameters
Refer to (2)
: Necessary
*1
Specify the same network No. as that of the GOT.
*2
Do not set the same station No. as that of the GOT.
POINT
POINT
POINT
When changing the network parameter
After writing the network parameter to the PLC CPU,
operate the PLC CPU ether turning OFF and then ON
or resetting.
Setting necessity
Set value
at GOT connection
0000
H
1
0 (fixed)
2
: As necessary
: Not necessary
(2) Routing parameter setting
Up to 64 [Transfer Network No.]s can be set.
However, the same transfer network number cannot be
set twice or more (multiple times).
Therefore, the one that can access to other station from
the request source host GOT is 64 kinds of [Transfer
Network No.]s.
Item
Target network No.
Relay network No.
Relay station No.
POINT
POINT
POINT
Routing parameter setting of request source
Routing parameter setting is also necessary for the
request source GOT.
For the setting, refer to the following.
8.3.4 Routing parameter setting
8. ETHERNET CONNECTION
8.4 PLC Side Setting
Range
1 to 239
1 to 239
1 to 64
8 - 43