Mitsubishi Electric GT1685 Connection Manual page 562

Got1000 series
Table of Contents

Advertisement

*2
Write a value to parameter Pr.185, Pr.186, Pr.188, or Pr.189
that corresponds to a signal within parentheses. Doing so
issues the corresponding run command (WS8 to WS11). For
the details of the inverter rameters, refer to the following.
Manual of the inverter used
(3) Alarm definition
*1
Device name
A0
A1
A2
A3
A4
A5
A6
A7
*1
Only reading is possible for A0 to A7.
These devices cannot be used for a write object (numerical input etc.).
(4) Parameter
The numbers of virtual devices for inverter (parameter
(Pr)), used by GOT, correspond to the inverter
parameter numbers.
For the inverter parameters, refer to the following.
Manual of the inverter being used
POINT
POINT
POINT
(1) Monitoring Pr.37
GOT cannot monitor the parameter (Pr.37) of
FREQROL-E500/S500(E)/F500J/D700/F700PJ/
E700.
(2) When setting "8888" or "9999" to inverter parameter (Pr)
"8888" and "9999" designate special function.
To set these numbers from GOT, designate a
number as shown below.
Set value of inverter side
8888
9999
(3) Precautions for setting calibration parameter
(Pr900 to Pr905)
When setting a calibration parameter (Pr900 to
Pr905), it is necessary to set the value below for
extension second parameter (SP108), depending on
the device number to be used and the inverter model.
Value to be set to extension
second parameter (SP108)
H00
H01
H02
(5) Programmed operation
The devices below correspond to the parameters
(Pr.201 to Pr.230) of FREQROL-A500 series.
Device name
PG0
to
PG9
Program set 1 (running frequency)
*1
Program set 1 (time)
PG10
to
PG19
PG20
to
PG29
Program set 1 (rotation direction)
15 - 52
15. INVERTER CONNECTION
15.6 Device Range that Can Be Set
Description
Second alarm in past
Latest alarm
Fourth alarm in past
Third alarm in past
Sixth alarm in past
Fifth alarm in past
Eighth alarm in past
Seventh alarm in past
Value specified by GOT
65520
65535
Description
Offset/gain
Analog
Analog value at terminal
Description
Device name
PG30
to
PG39
Program set 2 (running frequency)
*1
Program set 2 (time)
PG40
to
PG49
PG50
to
PG59
Program set 2 (rotation direction)
PG60
to
PG69
Program set 3 (running frequency)
*1
Program set 3 (time)
PG70
to
PG79
PG80
to
PG89
Program set 3 (rotation direction)
*1
To set the start time (PG10 to PG19, PG40 to PG49, PG70
to PG79), set hour or minute in the upper 8bits, and minute
or second in the lower 8bits.
Example) To set 13 hour 35 minute
Time to be set
Convert "hour" and "minute"
into hexadecimal.
Combine upper and lower 8-
Input H0D23 or 3363.
bit values.
(6) Special parameter
The numbers of the inverter's virtual devices (SP) used
for the GOT correspond to instruction codes of the
inverter communication function.
For instruction details, and values to be read and
written, refer to the following,
Manual of the inverter used
Device
Description
name
SP108
Second parameter changing
*1
Set frequency (RAM)
SP109
*1
SP110
Set frequency (RAM, E
*1*2
Output frequency
SP111
*2
Output current
SP112
*2
Output voltage
SP113
*2
Special monitor
SP114
SP115
Special monitor selection No.
Alarm definition all clear
SP116
Latest alarm, second alarm in past
SP117
Third alarm in past, fourth alarm in past
SP118
Fifth alarm in past, sixth alarm in past
Seventh alarm in past, eights alarm in
SP119
past
Inverter status monitor (extended)
SP121
Run command (extend)
Inverter status monitor
SP122
Run command
SP123
Communication mode
*3
All parameter clear
SP124
*3
Inverter reset
SP125
SP127
Link parameter extended setting
*1
GOT cannot monitor SP109 to SP111 if the conditions below
are satisfied at the same time.
(Only FREQROL-E500/S500(E)/F500J/D700/F700PJ/E700
series)
• Pr37
0
• SP127 = 1
*2
Only reading is possible for SP111 to SP114.
These devices cannot be used for a write object (numerical
input etc.).
*3
Only writing is possible for SP124 and SP125.
These devices cannot be used for read object.
Description
13H
35M
Remark
H0D
H23
HEX
-
Instruction
code
Read
Write
6C
H
6D
H
2
6E
PROM)
H
6F
H
70
H
71
H
72
H
73
H
-
74
H
75
H
76
H
77
H
79
H
7A
H
-
7B
H
-
-
7F
H
EC
H
ED
H
EE
H
-
-
-
-
F3
H
F4
H
-
-
-
-
F9
H
-
FA
H
FB
H
FC
H
FD
H
FF
H

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents