5.2 System Configuration

POINT
POINT
POINT
When "CONTROL BUS ERR" or "UNIT VERIFY ERR" occurs
It can be considered that noise due to a long bus connection cable causes a malfunction.
Check whether a signal line such as bus cable is placed near the equipment to operate. If the line is close to the
equipment, make a distance of 100mm or more from the equipment.
5.2.1

Connecting to QCPU

When one GOT is connected
Main base unit
Extension cable
PLC
Main base
Bus
Extension
extension
Main
*1
cable
connector
base
*2
box
-
-
Extension
cable
-
(13.2m or
less)
Main
base
A9GT
-
*3
-QCNB
Extension
cable
-
(13.2m or
less)
*1
For the extension cables, refer to the MELSEC-Q catalog (L(NA)08032).
*2
When installing the GOT 13.2m or more away from the main base unit, the bus extension
connector box is required.
Attach the bus extension connector box to the extension connector of the base unit.
Also, connect the connection cable to the bus extension connector box.
When using no extension base unit: Attach it to the main base unit.
When using the extension base unit: Attach it to the extension base unit on the last stage.
*3
When using Q00JCPU or Q00UJCPU, attach the bus extension connector to the extension base unit. (Connecting it to the main
base unit is not allowed)
*4
When using the following functions, use GT15-QBUS(2). GT15-75QBUS(2)L cannot be used.
Used for remote personal computer operation (serial), video display function, multimedia function, operation panel function,
external I/O function, RGB display function, report function (when using a PictBridge compatible printer), hard copy function
(when using a PictBridge compatible printer), sound output function, functions with the CF card unit or CF card extension unit,
Ethernet download, gateway function or MES interface function
However, Ethernet download, gateway function and MES interface function can be used for GT16 by using the Ethernet interface.
Bus extension
Extension base
connector box
unit
Connection cable
Extension base
Bus
Connection cable
extension
Extension
connector
base
*2
box
-
-
GT15-QC06B(0.6m)
GT15-QC12B(1.2m)
GT15-QC30B(3m)
GT15-QC50B(5m)
Extension
GT15-QC100B(10m)
-
base
GT15-QC06B(0.6m)
GT15-QC12B(1.2m)
-
-
GT15-QC30B(3m)
GT15-QC50B(5m)
GT15-QC100B(10m)
GT15-QC150BS(15m)
GT15-QC200BS(20m)
Extension
A9GT
GT15-QC250BS(25m)
base
-QCNB
GT15-QC300BS(30m)
GT15-QC350BS(35m)
GOT
GOT
*4
Model
Option device
GT15-75QBUSL
GT15-75QBUS2L
GT15-QBUS
GT15-QBUS2
- (Built into GOT)
GT15-75QBUSL
GT15-75QBUS2L
GT15-QBUS
GT15-QBUS2
- (Built into GOT)
5. BUS CONNECTION

5.2 System Configuration

1
2
3
Communication driver
Bus(Q)
4
Max. distance
5
Between main base and
GOT: 13.2m
(Including the extension
cable length)
6
Between main base and
GOT: 37m
(Including the extension
cable length)
7
8
5 - 7