18.4 GOT Side Settings

18.4.1 Setting communication
interface (Communication
settings)
Set the channel of the connected equipment.
2.
1.
Select [Common]
menu.
2.
The Controller Setting window is displayed. Select the
channel to be used from the list menu.
3.
Set the following items.
• Manufacturer: MITSUBISHI ELECTRIC
• Controller Type:
For GT16, GT15
MELSEC-QnA/Q/QS, MELDAS C6*
For GT14, GT11
MELSEC-QnA/Q, MELDAS C6*
• I/F: Interface to be used
• Driver:
For direct connection to CPU
AJ71QC24, MELDAS C6*
For ELSECNET/10 connection
MELSECNET/H
MELSECNET/10
For CC-Link (ID) connection
CC-Link Ver2 (ID)
CC-Link (ID)
For Ethernet connection
Ethernet (MELSEC), Q17nNC, CRnD-700
4.
The detailed setting is displayed after Manufacturer,
Controller Type, I/F, and Driver are set.
Make the settings according to the usage
environment.

18.4.2 Communication detail settings

Click the [OK] button when settings are completed.
18 - 8
18. CNC CONNECTION
18.4 GOT Side Settings
3.
4.
Click!
[Controller Setting] from the
POINT
POINT
POINT
The settings of connecting equipment can be
confirmed in [I/F Communication Setting].
For details, refer to the following.
1.1.2 I/F communication setting
18.4.2 Communication detail settings
Make the settings according to the usage environment.
(1) AJ71QC24, MELDAS C6*
Item
Description
Set this item when change the
transmission speed used for
Transmission
communication with the connected
Speed
equipment.
(Default: 19200bps)
Set this item when change the data
length used for communication with the
Data Bit
connected equipment.
(Default: 8bit)
Specify the stop bit length for
Stop Bit
communications.
(Default: 1bit)
Specify whether or not to perform a parity
check, and how it is performed during
Parity
communication.
(Default: Odd)
Set the number of retries to be
performed when a communication
Retry
timeout occurs.
(Default: 0time)
Set the time period for a communication
Timeout Time
to time out.
(Default: 3sec)
Set this item to adjust the transmission
timing of the communication request
Delay Time
from the GOT.
(Default: 0ms)
Range
4800bps,
9600bps,
19200bps,
38400bps,
57600bps,
115200bps
8bit (fixed)
1bit (fixed)
Odd (fixed)
0 to 5times
3 to 30sec
0 to 300ms