Plc Side Settings; System Configuration; Switch Setting Of Melsecnet/H Network Module - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

9.4 PLC Side Settings

This section describes the settings of the GOT and
MELSECNET/H network module in the case of system
configuration shown as 9.4.1.
When connecting the MELSECNET/H network module to
the MELSECNET/H network system, specify the
MELSECNET/H Mode or the MELSECNET/H Extended
Mode as a network type.
POINT
POINT
POINT
MELSECNET/H network module
For details of the MELSECNET/H network module,
refer to the following manual.
Q corresponding MELSECNET/H Network
System Reference Manual (PLC to PLC
network)
9.4.1

System configuration

9.4.4 [Controller Setting] of GT Designer3
<GOT>
(Use the default value for settings other
MELSECNET/H (PLC to PLC network)
<MELSECNET/H network module> *
(Use the default value for settings other than the following.)
Station No.
Mode
Network type
Network No.
Total stations
Network range assignment *

9.4.2 Switch setting of MELSECNET/H network module

(1) [Network parameter] of GX Developer
*1
The MELSECNET/H network module is mounted at slot 0 of
the base unit.
The start I/O No. of the MELSECNET/H network module is
set at "0".
*2
The network type must be set according to the number of
assignment of send points for each station.
When the number of assignment is 2000 bytes or less:
MELSECNET/H mode
When the number of assignment is 2000 bytes or more:
MELSECNET/H Extended Mode
POINT
POINT
POINT
When connecting to Q170MCPU
When connected to Q170MCPU, the start I/O No. of
the MELSECNET/H network module is set to "70".
9 - 12
9. MELSECNET/H CONNECTION (PLC TO PLC NETWORK)

9.4 PLC Side Settings

than the following.)
LB0100
to LB01FF
H
LW0100
to LW01FF
H
1
: 1
: Online (10Mbps)
: MNET/H mode (Control station)
: 1
: 2
2
:
LB0000
to LB00FF
H
H
LW0000
to LW00FF
H
H
9.4.2
Switch setting of
MELSECNET/H network
module
Set the station number setting switch and mode setting
switch.
QJ71LP21, QJ71LP21-25
QJ71LP21-25
RUN
MNG
T.PASS
D.LINK
SD
RD
ERR.
L ERR.
STATION NO.
X10
X1
IN
4
MODE
OUT
QJ71LP21
-25
H
H
QJ71BR11
QJ71BR11
RUN
MNG
D.LINK
T.PASS
SD
RD
L ERR.
ERR.
STATION NO.
X10
X1
4
MODE
QJ71BR11
QJ71LP21S-25
QJ71LP21S-25
RUN
MNG
EXT.PW
T.PASS
D.LINK
SD
RD
ERR.
L ERR.
STATION NO.
X10
(1)
X1
IN
(2)
EXT.PW
EXT.PW
MODE
+24V
+24V
24G
24G
OUT
(FG)
24G
QJ71LP21 S-25
(1)
(2)
(1)
4
(2)

Hide quick links: